Agilent BioTek 405 TS Washer

The 405 TS Microplate Washer is the gold standard in microplate washing. It features the patented Verify™ technology, which runs an automated QC check for manifold tube blockage, and visually reports any failed wells. The patented Ultrasonic Advantage™ can then be used to automatically and thoroughly clean the aspirate and dispense manifold. The 405 TS is the first self-checking, self-maintaining microplate washer available! Cell-based assays and microsphere-based assays are easily run with the 405 TS’s unique set of available features and modules for gentle washing, vacuum filtration and biomagnetic separation.

Agilent BioTek 405 TS Washer

The 405 TS Microplate Washer is the gold standard in microplate washing. It features the patented Verify™ technology, which runs an automated QC check for manifold tube blockage, and visually reports any failed wells. The patented Ultrasonic Advantage™ can then be used to automatically and thoroughly clean the aspirate and dispense manifold. The 405 TS is the first self-checking, self-maintaining microplate washer available! Cell-based assays and microsphere-based assays are easily run with the 405 TS’s unique set of available features and modules for gentle washing, vacuum filtration and biomagnetic separation.


General

Microplate types 96- and 384-well
Low profile and standard height
Solid and filter bottom (option)
Onboard software Create, edit or run multiple protocols
Software (computer control) LHC2 pc software
LHC2 Secure for 21 CFR Part 11 compliance (option)
SiLA Compliant driver (option)
Separation Biomagnetic separation, vacuum filtration (optional)
Shaking Programmable up to 60 minutes
Slow, medium, fast or variable
Soaking Programmable up to 60 minutes
Ultrasonic Advantage™ Yes (option)
Verify™ clog detection Yes (option)
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible
Microplate types 96- and 384-well
Low profile and standard height
Solid and filter bottom (option)
Onboard software Create, edit or run multiple protocols
Software (computer control) LHC2 pc software
LHC2 Secure for 21 CFR Part 11 compliance (option)
SiLA Compliant driver (option)
Separation Biomagnetic separation, vacuum filtration (optional)
Shaking Programmable up to 60 minutes
Slow, medium, fast or variable
Soaking Programmable up to 60 minutes
Ultrasonic Advantage™ Yes (option)
Verify™ clog detection Yes (option)
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible

Washing

Manifold types 96-well washing: 96-tube manifold - straight dispense tubes
96- and 384-well washing: 96-tube Dual-Action manifold - 20° angled dispense tubes
384-well washing (fast): 192-tube Dual-Action manifold - 7° angled dispense tubes
Volume range 25 - 3,000 µL/well, in 1 µL increments
Wash cycles 1 - 250
Buffer/reagent selection Auto switching (internal) for up to 4 buffers (option)
Supply bottle 4 L or 10 L (optional)
Dispense precision <3% CV: 300 µL/well (96-well washing)
<4% CV: 80 µL/well (384-well washing)
Residual volume < 2 µL/well (96- & 384-well plates)
96-tube manifold for 96 wells; 192-tube for 384 wells
Wash speed 96-wells, 300 µL/well, 3 cycles; <30 seconds
384-wells,100 µL/well, 3 cycles: <80 seconds
384-wells, 400 µL/well, 1 cycle: <20 seconds
Flow rates High flow to low flow
Optimized rates for cell assays
Sterilization Chemical
Vacuum filtration Selectable: Approximate final at 30 seconds:
Lowest: -38 mmHg
Low: -113 mmHg
Medium: -200 mmHg
High: -390 mmHg
Highest: -506 mmHgVacuum filtration time range: 5 to 999 seconds
Manifold types 96-well washing: 96-tube manifold - straight dispense tubes
96- and 384-well washing: 96-tube Dual-Action manifold - 20° angled dispense tubes
384-well washing (fast): 192-tube Dual-Action manifold - 7° angled dispense tubes
Volume range 25 - 3,000 µL/well, in 1 µL increments
Wash cycles 1 - 250
Buffer/reagent selection Auto switching (internal) for up to 4 buffers (option)
Supply bottle 4 L or 10 L (optional)
Dispense precision <3% CV: 300 µL/well (96-well washing)
<4% CV: 80 µL/well (384-well washing)
Residual volume < 2 µL/well (96- & 384-well plates)
96-tube manifold for 96 wells; 192-tube for 384 wells
Wash speed 96-wells, 300 µL/well, 3 cycles; <30 seconds
384-wells,100 µL/well, 3 cycles: <80 seconds
384-wells, 400 µL/well, 1 cycle: <20 seconds
Flow rates High flow to low flow
Optimized rates for cell assays
Sterilization Chemical
Vacuum filtration Selectable: Approximate final at 30 seconds:
Lowest: -38 mmHg
Low: -113 mmHg
Medium: -200 mmHg
High: -390 mmHg
Highest: -506 mmHgVacuum filtration time range: 5 to 999 seconds

Physical Characteristics

Power 100 - 240 Volts AC. 50/60 Hz
Dimensions 14" W x 17" D x 10" H
(35.6 x 43.2 x 25.4 cm)
Weight With internal buffer switching - 36 lbs (16.5 kg)
Without - 30 lbs (13.5 kg)
Power 100 - 240 Volts AC. 50/60 Hz
Dimensions 14" W x 17" D x 10" H
(35.6 x 43.2 x 25.4 cm)
Weight With internal buffer switching - 36 lbs (16.5 kg)
Without - 30 lbs (13.5 kg)

Regulatory

Regulatory CE and TUV marked. ROHS compliant. In Vitro Diagnostic use models are available.

Configurations

Part #
384-well
96-well
Optimized Cell Washing
4-Buffer Switching
Ultrasonic Advantage
Verify™ technology
Biomagnetic Separation**
Vacuum Filtration**
405TSHT
 *
405TSHTV
 *
405TSU
405TSUV
 •
405TSUS
405TSUSQ
 •
405TSUVS
405TSUVSQ
 •
405TSR
405TSRV
405TSRS
405TSRSQ
405TSRVS
405TSRVSQ

* 96-well washing available with optional manifold PN 1170010, sold separately
** With available accessory module sold separately