Agilent BioTek MultiFlo FX Multi-Mode Dispenser

MultiFlo™ FX is an automated multi-mode reagent dispenser for 6- to 1536-well microplates. MultiFlo FX incorporates several unique technologies in its modular design, such as Parallel Dispense, RAD™ Random Access Dispense and the new, patent-pending AMX™ Automated Media Exchange modules to facilitate a variety of liquid handling applications from 2D and 3D cell culture to concentration normalization assays, ELISA, bead-based assays and more. A fully configured MultiFlo FX replaces up to five liquid handlers, saving space, time and instrumentation budgets. MultiFlo FX integrates to the BioSpa™ 8 Automated Incubator and a BioTek imager or multi-mode reader, for complete workflow automation for many cell imaging and biochemical applications.

Agilent BioTek MultiFlo FX Multi-Mode Dispenser

MultiFlo™ FX is an automated multi-mode reagent dispenser for 6- to 1536-well microplates. MultiFlo FX incorporates several unique technologies in its modular design, such as Parallel Dispense, RAD™ Random Access Dispense and the new, patent-pending AMX™ Automated Media Exchange modules to facilitate a variety of liquid handling applications from 2D and 3D cell culture to concentration normalization assays, ELISA, bead-based assays and more. A fully configured MultiFlo FX replaces up to five liquid handlers, saving space, time and instrumentation budgets. MultiFlo FX integrates to the BioSpa™ 8 Automated Incubator and a BioTek imager or multi-mode reader, for complete workflow automation for many cell imaging and biochemical applications.


General

Microplate types Dispensing (peri pump and syringe)
96-, 384- and 1536-well standard, deep and PCR plates; 6-. 12-, 24- and 48-well plates (dispense tip configurable)
Washing
96-. 384-well standard plates; 6-, 12-, 24-,and 48-well plates (with compatible manifold configuration)
Onboard software Create, edit or run multiple protocols
Software (computer control) LHC2 Software
LHC2 Secure for 21 CFR Part 11 compliance (option)
SiLA Compliant driver (option)
Shaking Programmable up to 60 minutes
Slow, medium, fast or variable
Soaking Programmable up to 60 minutes
USB ports (2) For protocol storage/transfer and for optional external mouse or keyboard
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible
Microplate types Dispensing (peri pump and syringe)
96-, 384- and 1536-well standard, deep and PCR plates; 6-. 12-, 24- and 48-well plates (dispense tip configurable)
Washing
96-. 384-well standard plates; 6-, 12-, 24-,and 48-well plates (with compatible manifold configuration)
Onboard software Create, edit or run multiple protocols
Software (computer control) LHC2 Software
LHC2 Secure for 21 CFR Part 11 compliance (option)
SiLA Compliant driver (option)
Shaking Programmable up to 60 minutes
Slow, medium, fast or variable
Soaking Programmable up to 60 minutes
USB ports (2) For protocol storage/transfer and for optional external mouse or keyboard
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible

Washing

Manifold types 96- and 384-well washing: 8-tube manifold
6-, 12-, 24-, 48-well washing: Custom manifolds available
Volume range 20-30,000 µL/well
Wash cycles 1-10
Supply bottle 2 L
Dispense accuracy +3%
Dispense precision 96-/384-well plates, 300 µL/well: <3% CV
6-well plates, 5560 µL/well: <5% CV
Residual volume 96-well plate, 300 µL/well: < 2 µL/well
Wash speed 96-wells, 8-tube manifold, 3 cycles, >300 µL/well: <130 seconds
Wash volume 20-30,000 µL/well
Waste bottle 2L
Flow rates 140-422 µL/well/second
Sterilization Chemical
Manifold types 96- and 384-well washing: 8-tube manifold
6-, 12-, 24-, 48-well washing: Custom manifolds available
Volume range 20-30,000 µL/well
Wash cycles 1-10
Supply bottle 2 L
Dispense accuracy +3%
Dispense precision 96-/384-well plates, 300 µL/well: <3% CV
6-well plates, 5560 µL/well: <5% CV
Residual volume 96-well plate, 300 µL/well: < 2 µL/well
Wash speed 96-wells, 8-tube manifold, 3 cycles, >300 µL/well: <130 seconds
Wash volume 20-30,000 µL/well
Waste bottle 2L
Flow rates 140-422 µL/well/second
Sterilization Chemical

Dispensing - Peristaltic pump (Multi-Channel)

Manifold types 1 x 8 - sapphire jeweled 316 SS, 316 SS or polypropylene tips, with 1, 5 or 10 µL tubing
Fluid delivery 1 or 2 peristaltic pumps
Dispense speed 96 wells, 5 µL cass, 10 µL/ well: 3 seconds
96 wells, 5 µL cass, 20 µL/ well: 3.5 seconds
384 wells, 5 µL cass, 5 µL/ well: 6.5 seconds
384 wells, 10 µL cass, 10 µL/ well: 8 seconds
384 wells, 1 µL cass, 1 µL/ well: 6 seconds
1536 wells, 1 µL cass, 1 µL/ well: 21 seconds
Volume range 500 nL - 3,000 µL/well, selectable in 1 µL increments
Flow rates User programmable rates from high to low
Dispense performance 1 µL cassette: recommended range: 1 - 50 µL
Accuracy: +5% at 1 µL
Precision: <5% CV at 1 µL
<10% CV at 500 nL
Minimum Prime Volume: 1.20 mL

5 µL cassette: recommended range: 5 - 2,500 µL
Accuracy: +2.0% at 5 µL
Precision: <2.5% CV at 5 µL
Minimum Prime Volume: 4.23 mL

10 µL cassette: recommended range: 10 - 3,000 µL
Dispense Accuracy: +2.0% at 10 µL
Dispense Precision: <2.0% CV at 10 µL
Minimum Prime Volume: 7.36 mL

Recommended cassette replacement interval 1 µL Cassette: 1,000 384-well microplates at 5 µL well
5 µL Cassette: 1,000 96-well microplates at 50 µL well
10 µL Cassette: 1,000 96-well microplates at 100 µL well
Sterilization Autoclave, chemical
Manifold types 1 x 8 - sapphire jeweled 316 SS, 316 SS or polypropylene tips, with 1, 5 or 10 µL tubing
Fluid delivery 1 or 2 peristaltic pumps
Dispense speed 96 wells, 5 µL cass, 10 µL/ well: 3 seconds
96 wells, 5 µL cass, 20 µL/ well: 3.5 seconds
384 wells, 5 µL cass, 5 µL/ well: 6.5 seconds
384 wells, 10 µL cass, 10 µL/ well: 8 seconds
384 wells, 1 µL cass, 1 µL/ well: 6 seconds
1536 wells, 1 µL cass, 1 µL/ well: 21 seconds
Volume range 500 nL - 3,000 µL/well, selectable in 1 µL increments
Flow rates User programmable rates from high to low
Dispense performance 1 µL cassette: recommended range: 1 - 50 µL
Accuracy: +5% at 1 µL
Precision: <5% CV at 1 µL
<10% CV at 500 nL
Minimum Prime Volume: 1.20 mL

5 µL cassette: recommended range: 5 - 2,500 µL
Accuracy: +2.0% at 5 µL
Precision: <2.5% CV at 5 µL
Minimum Prime Volume: 4.23 mL

10 µL cassette: recommended range: 10 - 3,000 µL
Dispense Accuracy: +2.0% at 10 µL
Dispense Precision: <2.0% CV at 10 µL
Minimum Prime Volume: 7.36 mL

Recommended cassette replacement interval 1 µL Cassette: 1,000 384-well microplates at 5 µL well
5 µL Cassette: 1,000 96-well microplates at 50 µL well
10 µL Cassette: 1,000 96-well microplates at 100 µL well
Sterilization Autoclave, chemical

Dispensing - Syringe pump

Manifold types 96- and 384-well dispensing:
One 16-tube (2 x 8) manifolds - 316 SS tubes
Two 16-tube (1 x 16) manifolds - 316 SS tubes

1536-well dispensing:
Two 32-tube (1 x 32) manifolds - sapphire jeweled 316 SS or 316 SS tubes
6- to 48-well dispensing: custom autoclavable manifolds available

Fluid delivery Two positive displacement syringe drives
Dispense speed 20 µL /well, 96 wells, 1 x16 tubes:: 5 seconds
20 µL /well, 384 wells, 1 x16 tubes:: 14 seconds
3 µL /well, 1536 wells, 2 x 32 tubes:: 7 seconds
Volume range 3 - 3,000 µL/well selectable in 1 µL increments
Minimum Prime Volume: 12 mL
Flow rates User programmable rates from high to low
Dispense accuracy +1 µL at 5 µL
+1 µL at 20 µL
+1% at 100 µL
Dispense precision <5% CV at 5 µL
<2.5% CV at 20 µL
<1% CV at 100 µL
Supply bottle 1 L or 2 L
Sterilization Chemical, autoclavable option
Manifold types 96- and 384-well dispensing:
One 16-tube (2 x 8) manifolds - 316 SS tubes
Two 16-tube (1 x 16) manifolds - 316 SS tubes

1536-well dispensing:
Two 32-tube (1 x 32) manifolds - sapphire jeweled 316 SS or 316 SS tubes
6- to 48-well dispensing: custom autoclavable manifolds available

Fluid delivery Two positive displacement syringe drives
Dispense speed 20 µL /well, 96 wells, 1 x16 tubes:: 5 seconds
20 µL /well, 384 wells, 1 x16 tubes:: 14 seconds
3 µL /well, 1536 wells, 2 x 32 tubes:: 7 seconds
Volume range 3 - 3,000 µL/well selectable in 1 µL increments
Minimum Prime Volume: 12 mL
Flow rates User programmable rates from high to low
Dispense accuracy +1 µL at 5 µL
+1 µL at 20 µL
+1% at 100 µL
Dispense precision <5% CV at 5 µL
<2.5% CV at 20 µL
<1% CV at 100 µL
Supply bottle 1 L or 2 L
Sterilization Chemical, autoclavable option

Dispensing: RAD (Random Access Module)

Labware types Single tip: 6-, 12-, 24-, 48-, 96-, 384-well plates; low profile
standard height and deep well formats; PCR trays and microtubes
8-to-1 tip: 6-, 12-, and 24-well plates
Manifold Types RAD single, with plastic or steel tip with 1, 5 or 10 tubing, 7° angle
RAD 8-to-1 plastic tip, with 5 µL tubing, angled bulk dispense chute
Volume range 500 nL - 30,000 µL
Minimum prime volume 1 µL cass, 18": 90 µL ; 1 µL cass, 30": 150 µL
5 µL cass, 18": 320 µL; 1 µL cass, 30": 530 µL
10 µL cass, 18": 555 µL; 10 µL cass, 30": 920 µL
Dispense speed (high flow) 1 µL cass, 1 µL/well: 19s (96 wells) 55s (384 wells)
1 µL cass, 10 µL/well: 33s (96 wells), 112s (384 wells)
5 µL cass, 5 µL/well: 19s (96 wells), 58s (384 wells)
5 µL cass, 100 µL/well: 76s (96 wells), 286s (384 wells)
10 µL cass, 10 µL/well: 21s (96 wells), 66s (384 wells)
10 µL cass, 100 µL/well: 70s (96 wells), 259s (384 wells)
Dispense performance 1 µL cass (med), 0.5 µL/well: Precision 10% CV
1 µL cass (med), 1 µL/well: Accuracy + 10%, Precision 10% CV
1 µL cass (med), >2 µL/well: Accuracy + 5%, Precision 5% CV
5 µL cass (high), 5 µL/well: Accuracy + 4%, Precision 5% CV
5 µL cass (high), >10 µL/well: Accuracy + 2%, Precision 2.5% CV
10 µL cass (high), 10 µL/well: Accuracy + 4%,Precision 4% CV
10 µL cass (high), >20 µL/well: Accuracy + 2%, Precision 2 %CV
8-to 1 cass(high), 40 µL/well: Accuracy + 4%
8-to 1 cass (high), >10 µL/well: Precision 2.5%CV
8- to 1cass(high), >80 µL/well: Accuracy + 2%
Labware types Single tip: 6-, 12-, 24-, 48-, 96-, 384-well plates; low profile
standard height and deep well formats; PCR trays and microtubes
8-to-1 tip: 6-, 12-, and 24-well plates
Manifold Types RAD single, with plastic or steel tip with 1, 5 or 10 tubing, 7° angle
RAD 8-to-1 plastic tip, with 5 µL tubing, angled bulk dispense chute
Volume range 500 nL - 30,000 µL
Minimum prime volume 1 µL cass, 18": 90 µL ; 1 µL cass, 30": 150 µL
5 µL cass, 18": 320 µL; 1 µL cass, 30": 530 µL
10 µL cass, 18": 555 µL; 10 µL cass, 30": 920 µL
Dispense speed (high flow) 1 µL cass, 1 µL/well: 19s (96 wells) 55s (384 wells)
1 µL cass, 10 µL/well: 33s (96 wells), 112s (384 wells)
5 µL cass, 5 µL/well: 19s (96 wells), 58s (384 wells)
5 µL cass, 100 µL/well: 76s (96 wells), 286s (384 wells)
10 µL cass, 10 µL/well: 21s (96 wells), 66s (384 wells)
10 µL cass, 100 µL/well: 70s (96 wells), 259s (384 wells)
Dispense performance 1 µL cass (med), 0.5 µL/well: Precision 10% CV
1 µL cass (med), 1 µL/well: Accuracy + 10%, Precision 10% CV
1 µL cass (med), >2 µL/well: Accuracy + 5%, Precision 5% CV
5 µL cass (high), 5 µL/well: Accuracy + 4%, Precision 5% CV
5 µL cass (high), >10 µL/well: Accuracy + 2%, Precision 2.5% CV
10 µL cass (high), 10 µL/well: Accuracy + 4%,Precision 4% CV
10 µL cass (high), >20 µL/well: Accuracy + 2%, Precision 2 %CV
8-to 1 cass(high), 40 µL/well: Accuracy + 4%
8-to 1 cass (high), >10 µL/well: Precision 2.5%CV
8- to 1cass(high), >80 µL/well: Accuracy + 2%

Media Exchange: AMX (Automated Media Exchange Module)

Microplate types 96- and 384-well standard (ANSI/SBS)
Manifold types Two 8-channel autoclavable manifolds, tube-in-tube design
Cassettes Autoclavable cassettes with with 5 µL tubing
Dispense Precision <5% CV
Dispense Accuracy <5%
Aspiration uniformity <5%
Sterilization method Cassettes and manifolds: chemical and autoclavable
Microplate types 96- and 384-well standard (ANSI/SBS)
Manifold types Two 8-channel autoclavable manifolds, tube-in-tube design
Cassettes Autoclavable cassettes with with 5 µL tubing
Dispense Precision <5% CV
Dispense Accuracy <5%
Aspiration uniformity <5%
Sterilization method Cassettes and manifolds: chemical and autoclavable

Physical Characteristics

Power 100 - 240 Volts AC. 50/60 Hz
Dimensions Base instrument: 17.19"W x 11.75" D x 8" H (43.51 x 29.21 x 20.32 cm)
Weight Base instrument:
19.5 lbs (8.8 Kg)
Power 100 - 240 Volts AC. 50/60 Hz
Dimensions Base instrument: 17.19"W x 11.75" D x 8" H (43.51 x 29.21 x 20.32 cm)
Weight Base instrument:
19.5 lbs (8.8 Kg)

Regulatory

Regulatory CE and TUV marked, RoHS Compliant. Models for In Vitro Diagnostic use are available.

Configurations

Part # Description
MFXP1
MultiFlo FX with 1 module arm, 1 peristaltic dispense pump, 1 peri-pump cassette with plastic tips.
MFXP2
MultiFlo FX with 2 module arms, 1 peristaltic dispense pump. Includes 1 peri-pump cassette with plastic tips.
MFXP2R
MultiFlo FX with RAD single channel dispenser. Includes 2 module arms, 2 peristaltic dispense pumps, 1 RAD manifold, and tubing included.

 

Optional Modules

Compatible With MFXP1 MFXP2 MFXP2R
7210010
Secondary peripump module. Includes module and choice of (1) one peri-pump cassette with plastic tips.
7210008
Dual syringe pump module (autoclavable). Includes module with two syringe pumps, (2) autoclavable bottles (PN 7140511) and (1) autoclavable tubing set (PN 7183006). Manifold(s) are required and must be purchased separately, see "Syringe Pump Dispenser Module" section for available manifolds.
7210009
Dual syringe pump module (non-autoclavable).  Includes module with two pumps, (2) non-autoclavable bottles (PN 4070515) and (1) non-autoclavable tubing set (PN 7183002).  Manifold(s) are required and must be purchased separately, see "Syringe Pump Dispenser Module" section for available manifolds.
1260023
Wash module. Includes pump, bottles, tubing and one 96/384 wash manifold. Other manifolds available, order separately.
1260041
AMX Automated Media Exchange module. Includes secondary peri pump module, AMX dispense and aspirate manifolds. Two cassettes (PN 1260035) are required, order separately.